Replace and Program Image Processing Module
NOTE:
Due to continuous improvements, the on screen selections may vary from instructions below.
Upon replacement of the K124 Image Processing Module, perform the following procedures:
- Install the EL-49642 SPS Programming Support Tool to maintain system voltage.
- Ensure the programming tool is equipped with the latest software and is securely connected to the data link connector. If there is an interruption during programming, programming failure or control module damage may occur.
- Ignition/Vehicle OFF.
- Access the Service Programming System (SPS) and follow the on-screen instructions.
- On the SPS Supported Controllers screen, select K124 Image Processing Module - Programming and follow the on-screen instructions.
- Perform Serial Data Authentication Configuration. Serial Data Authentication Configuration
- Perform Vehicle Dynamic Sensor Offset Calibration. Vehicle Dynamic Sensor Offset Calibration
- Perform All Cameras Alignment Learn. Surround Vision Camera Calibration (cameras wired to K124 Image Processing Module)