Remote Keyless Entry (RKE) Control Module Does Not Lock Or Unlock Right & Side Doors
- Disconnect RKE control module connectors. Connect fused jumper wire between connector C1 terminal "D" (Light Blue wire) and connector C2 terminal "A" (Orange wire). If right and side doors lock, go to next step. If right and side doors do not lock, go to step 4).
- Connect fused jumper wire between connector C1 terminals "E" (White wire) and "A" (Orange wire). If right and side doors do not unlock, go to next step. If right and side doors do unlock, replace RKE control module.
- Place either front door lock switch in UNLOCK position. Connect test light between RKE control module connector C1 terminal "E" (White wire) and ground. If test light comes on, replace RKE control module. If test light does not light, repair open circuit in White wire.
- Place either front door lock switch in LOCK position. Connect test light between RKE control module connector C1 terminal "D" (Light Blue wire) and ground. If test light comes on, replace RKE control module. If test light does not come on, repair open circuit in Light Blue wire.