Circuit Description
The high speed cooling fan relay is controlled by the electronic control module (ECM). The ECM applies a ground to the high speed cooling fan relay, while also applying ground to the low speed cooling fan relay, to achieve high speed cooling fan operation. The ECM determines when to activate the high speed cooling fan relay depending on the coolant temperature and the A/C system high side pressure.