Circuit/System Testing
WARNING: This page is about a different car, the 2010 Cadillac SRX. However, it is still accessible from the selected car via links, so may be relevant.
- Ignition OFF, disconnect the harness connector at the S43 ultrasonic intrusion sensor disable switch.
- Test for less than 10Ω between the ground circuit terminal 2 and ground.
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Ignition OFF, connect the harness connector at the S43 ultrasonic intrusion sensor disable switch. Disconnect the harness connector at the B67 ultrasonic intrusion sensor.
- Test for less than 10Ω between the ground circuit terminal 5 and ground.
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Ignition ON, verify a test lamp illuminates between the B+ circuit terminal 3 and ground.
- If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.
- Test for less than 1V between the signal circuit terminal 1 and ground.
- If greater than the specified range, test the signal circuit for a short to voltage.
- Ignition OFF, test for infinite resistance between the signal circuit terminal 1 and ground.
- If not the specified value, test the signal circuit for a short to ground. If the circuit tests normal, test or replace the S43 ultrasonic intrusion sensor disable switch.
- Content theft disable switch closed, test for less than 10Ω between the signal circuit terminal 1 and ground.
- If greater than the specified range, test the signal circuit for an open/high resistance. If the circuit tests normal, test or replace the S43 ultrasonic intrusion sensor disable switch.
- Ignition ON, verify the content theft disable indicator is not illuminated.
- If the indicator is illuminated, test the control circuit terminal 2 for a short to voltage.
- Install a 3A fused jumper wire between the control circuit terminal 2 and B+. Verify the content theft disable indicator is illuminated.
- If the indicator is not illuminated, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, test or replace the S43 ultrasonic intrusion sensor disable switch.
- Disconnect the X6 harness connector at the K9 BCM.
- Test for less than 1V between the serial data circuit terminal 16 and ground.
- If greater than the specified range, test the serial data circuit for a short to voltage.
- Ignition OFF, test for infinite resistance between the serial data circuit terminal 16 and ground.
- If not the specified value, test the serial data circuit for a short to ground.
- Test for less than 2Ω between the serial data circuit terminal 16 at the K9 BCM harness connector X6 and the serial data circuit terminal 4 at the B67 ultrasonic intrusion sensor harness connector.
- If greater than the specified range, test the serial data circuit for an open/high resistance.
- If all circuits test normal, replace the B67 ultrasonic intrusion sensor.