Typical Scan Tool Data
MAP Sensor
| Circuit | Short to Ground | Open | Short to Voltage |
|---|---|---|---|
| Operating Conditions:
Engine operating in closed loop, idling and accessories OFF Parameter Normal Range: 26-52 kPa (3.8-7.6 PSI) (varies with altitude) |
|||
| 5 V Reference | 0 kPa (0 PSI) | 0 kPa (0 PSI) | 127 kPa (18.4 PSI) |
| Signal | 0 kPa (0 PSI) | 0 kPa (0 PSI) | 127 kPa (18.4 PSI)* |
| Low Reference | - | 127 kPa (18.4 PSI) | - |
| * Internal ECM or sensor damage may occur if the circuit is shorted to B+. | |||