Installation Procedure
- Install a NEW lower exhaust gas recirculation pipe gasket (5).
Courtesy of GENERAL MOTORS COMPANY
- Install a NEW upper exhaust gas recirculation pipe gasket (1).
- Install the exhaust gas recirculation pipe (3).
- Install the 2 exhaust gas recirculation pipe bolts (2) and tighten to 8 N.m (71 lb in).
- Install the 2 exhaust gas recirculation pipe bolts (4) and tighten to 9 N.m (80 lb in).
- Install the EGR valve temperature sensor position 2. Refer to Exhaust Gas Recirculation Valve Temperature Sensor Replacement - Position 2 .
- Install the engine sight shield. Refer to Engine Sight Shield Replacement
.