Removal Procedure
WARNING: This page is about a different variant/trim than selected.
- Disable the high voltage system. High Voltage Disabling
Drive Motor Generator Control Module Tray (2) - Remove - Drive Motor Generator Control Module Tray Replacement
High Voltage Electrical Connector (1) - Disconnect
- Electrical Connector (2) - Disconnect
- Release the retainers. (3)
Battery Positive Junction Block Cable Bolt (1)@Accessory DC Power Control Module - Remove
- Retainer (2) - Disengage
- Battery Positive Junction Block Cable (3) - Reposition away
- Drive Motor Battery Impact Absorber (4) - Remove
Accessory DC Power Control Module Nut (1) - Remove [2X]
- Accessory DC Power Control Module Bolt (2) - Remove [2X]
- Accessory DC Power Control Module (3) - Remove