Installation Procedure
- Communication Interface Module Battery (2) - Install
- Communication Interface Module Battery Bolt (1) - Install and tighten - Fastener Specifications
- Telematic Control Module (1) - Install
- Connect the electrical connectors.
- Floor Front Air Outlet Duct - Left Side (1) - InstallWARNING:
Upon installing the floor duct to the side of the HVAC case, it is necessary to verify duct opening is completely installed, surrounding the HVAC case outlet port. Failure to do so could result in the duct falling downward, with the potential to interfere with driver's legs and gas/brake pedal operation.
- Floor Front Air Outlet Duct Bolt (1) - Install and tighten - Fastener Specifications
- Instrument Panel Lower Trim Panel Insulator (1) - Install
- Instrument Panel Lower Insulator Retainer (1) - Install [2x]
- Perform the necessary programming and setup procedure:Control Module References
CAUTION:
Refer to Fastener Caution .