part number is located on the side of the generator
Type Melco
Minimum Test Amperage 110 Ampere (A)
Engine RPM 2500 +/-20 Revolutions Per Minute (rpm)
Voltage output 14.0 +/-0.5 Volts (V)
Field Current 5 +/- 0.1 Ampere (A)