LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Chrysler >> 2002 >> Prowler V6-3.5L VIN G >> Repair and Diagnosis >> Heating and Air Conditioning >> Control Assembly >> Testing and Inspection >> HVAC Control Module Test
April 5, 2026: LEMON Manuals is launched! Read the announcement.

HVAC Control Module Test

The control switch and timer circuit may be tested in the vehicle with or without a DRBIII(R) scan tool.

Testing With The DRBIII(R) Scan Tool
If using the DRBIII(R) scan tool, refer to the proper Body Diagnostic Procedures manual.

Fig.4 HVAC Control Module Connectors:




Testing Without The DRBIII(R) Scan Tool
1. Remove the control switch from console and do not disconnect control switch.
2. Using a ohmmeter, check leads between Pins 5 and 8 of the 8-way connector. Depress the rear window defogger button and the resistance reading should be 500 to 520 ohms. If not OK, replace HVAC. If OK, check:
- Rear window relay (EBL)
- Blown fuse Cut wire
- Poor ground
- Poor connection
- Defective BCM
- Bulkhead connector inoperative

Refer to Wiring Diagrams for circuit information.