Carburetor Switch Test
- Turn ignition off and disconnect 10-wire connector from computer. With throttle completely closed, check continuity with ohmmeter leads connected to cavity 7 and ground.NOTE: Grounding carburetor switch eliminates spark advance on most systems and provides fixed air/fuel ratio on feedback carburetor systems.
- If no continuity is read, check wire from cavity 7 to carburetor switch terminal. Also check carburetor switch for proper operation.
- Open throttle and check for continuity from cavity 7 to ground. There should be no continuity. If readings are not as outlined, replace carburetor switch.