LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Dodge and Ram >> 1992 >> Caravan Base, 2.5 K, Standard >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls - Tests W/Codes - Body Control Computer >> Self-Diagnostic Tests >> Test 48 - Repairing Faulty Washer Fluid Level Switch >> TEST 48A - Repairing Faulty Washer Fluid Level Switch
April 5, 2026: LEMON Manuals is launched! Read the announcement.

TEST 48A - Repairing Faulty Washer Fluid Level Switch

NOTE: For connector terminal identification, see CONNECTOR IDENTIFICATION . For appropriate wiring diagram, see WIRING DIAGRAMS .
  1. Check washer fluid level. If washer fluid is not full, add fluid as necessary. Perform VERIFICATION TEST - VERIFICATION OF REPAIRS . If washer fluid is full, using DRB-II, read washer fluid switch status. If DRB-II displays CIRCUIT OPEN, go to step 4). If DRB-II does not display CIRCUIT OPEN, disconnect washer fluid level switch connector.
  2. If DRB-II displays CIRCUIT OPEN, replace washer fluid level switch. Perform VERIFICATION TEST - VERIFICATION OF REPAIRS . If DRB-II does not display CIRCUIT OPEN, turn ignition switch to OFF position. Disconnect body controller Natural connector. Body controller is located under left side of instrument panel.
  3. Check connector, and clean or repair connector as necessary. Place DRB-II in ohmmeter mode. Probe terminal No. 19 (Black/Tan wire) of body controller Natural connector. If resistance is less than 5 ohms, repair short to ground in Black/Tan wire. Perform VERIFICATION TEST - VERIFICATION OF REPAIRS . If resistance is more than 5 ohms, replace body controller. Perform VERIFICATION TEST - VERIFICATION OF REPAIRS .
  4. If DRB-II displays OPEN CIRCUIT in step 1), disconnect washer fluid level switch connector. Connect a jumper wire between Black/Tan and Black wires of washer fluid level switch connector. If DRB-II displays CIRCUIT CLOSED, replace washer fluid level switch. Perform VERIFICATION TEST - VERIFICATION OF REPAIRS . If DRB-II does not display CIRCUIT CLOSED, disconnect jumper wire.
  5. Connect a jumper wire between Black/Tan wire of washer fluid level switch connector and ground. If DRB-II displays CIRCUIT CLOSED, repair open Black wire. Perform VERIFICATION TEST - VERIFICATION OF REPAIRS . If DRB-II does not display CIRCUIT CLOSED, access body controller.
  6. Body controller is located under left side of instrument panel. Connect a jumper wire between terminal No. 19 (Black/Tan wire) at body controller Natural connector and ground. If DRB-II displays CIRCUIT CLOSED, repair open Black/Tan wire. Perform VERIFICATION TEST - VERIFICATION OF REPAIRS . If DRB-II does not display CIRCUIT CLOSED, replace body controller. Perform VERIFICATION TEST - VERIFICATION OF REPAIRS .