Test 21A - Diagnosing Side Door Memory Lock
NOTE:
For connector terminal identification, see CONNECTOR IDENTIFICATION. For wiring diagrams, see WIRING DIAGRAMS
article in the ENGINE PERFORMANCE Section. Perform TEST VER - 1A after each repair.
CAUTION:
Always turn ignition switch to OFF position prior to disconnecting or connecting any module connector.
- Turn ignition on and ensure left front door is open and side door is closed. Using DRB-II, actuate auto door locks. If side door does not lock, go to step 5). If side door locks, stop door lock actuation.
- Ensure side door is closed and read door ajar switch status. If DRB-II does not display SIDE DR AJAR:OPEN, go to TEST 42A.
- If DRB-II displays SIDE DR AJAR:OPEN, open side door. Read door ajar switch status. If DRB-II does not display SIDE DR AJAR:CLOSED, go to TEST 42A.NOTE: Left front door MUST be open in following steps.
- If DRB-II displays SIDE DR AJAR:CLOSED, turn ignition off and remove key. Read key-in ignition status. If DRB-II does not display KEY IN IGN:OPEN, go to TEST 39B. If DRB-II displays KEY IN IGN:OPEN, replace body controller. Body controller is located under left side of instrument panel.
- Stop door lock actuation. If front doors do not lock, go to TEST 19A. If front doors lock, repair side door lock circuit.