Test 13A - Repairing Door Ajar Warning Light
- Ensure all doors and liftgate are adjusted and aligned. Close all doors. Using DRB-II, read left front door ajar switch status. If DRB-II displays CIRCUIT CLOSED, go to TEST 40A. If DRB-II does not display CIRCUIT CLOSED, open left front door. If DRB-II does not display CIRCUIT CLOSED, go to TEST 40A.
- If DRB-II displays CIRCUIT CLOSED, use DRB-II to read right front door ajar switch status. If DRB-II displays CIRCUIT CLOSED, go to TEST 41A. If DRB-II does not display CIRCUIT CLOSED, open right front door. If DRB-II does not display CIRCUIT CLOSED, go to TEST 41A.
- If DRB-II displays CIRCUIT CLOSED, read side door ajar switch status using DRB-II. If DRB-II displays or does not display CIRCUIT CLOSED, go to TEST 42A.