Test 19D - Diagnosing Door Unlock Circuit
NOTE:
For connector terminal identification, see CONNECTOR IDENTIFICATION. For wiring diagrams, see WIRING DIAGRAMS
article in the ENGINE PERFORMANCE Section. Perform TEST VER - 1A after each repair.
CAUTION:
Always turn ignition switch to OFF position prior to disconnecting or connecting any module connector.
- Turn ignition off. Disconnect door unlock relay. Using DRB-II in ohmmeter mode, measure resistance of switched battery feed circuit at door unlock relay connector terminal No. 14 (Pink/Violet wire).
- If resistance is more than 5 ohms, repair open Pink/Violet wire. If resistance is less than 5 ohms, replace door lock switch.