Test 41A - Inoperative (Courtesy Light) Bulb
NOTE:
For connector terminal identification, see CONNECTOR IDENTIFICATION
. For appropriate wiring diagram, see WIRING DIAGRAMS
at end of article.
Remove inoperative (courtesy light) bulb. If bulb filament is open, replace bulb. Perform VERIFICATION PROCEDURE VER-1. If bulb filament is okay, disconnect inoperative light assembly. With DRB-II in voltmeter mode, check voltage on light assembly connector fused battery feed circuit (Pink wire). If voltage is more than 10 volts, repair open ground circuit for inoperative light assembly. Perform VERIFICATION PROCEDURE VER-1. If voltage is less than 10 volts, repair open circuit in Pink wire to inoperative courtesy light. Perform VERIFICATION PROCEDURE VER-1.