Test 20G - Repairing Power Door Lock Problems W/ RKE
CAUTION:
Always turn ignition off prior to disconnecting or connecting any module connector.
- Remove door unlock relay (third relay from right, bottom row) from micro relay center located behind center console. Using DRB in ohmmeter mode, check resistance of ground circuit (Black wire) at unlock relay connector terminal "E". If resistance is more than 5 ohms, repair open Black wire. Perform TEST VER-1B . If resistance is less than 5 ohms, go to next step.
- Using DRB in voltmeter mode, check voltage on door lock switch unlock output circuit (Pink/Violet wire) at door unlock relay connector. Depress door lock switch to UNLOCK position while observing DRB voltage. If voltage is more than 10 volts, replace door unlock relay. Perform TEST VER-1B. If voltage is less than 10 volts, repair open Pink/Violet wire. Perform TEST VER-1B.