Control Circuit Test
The starter control circuit is comprised of the following components:
- Starter Motor With Integral Solenoid
- Engine Starter Motor Relay
- Clutch Interlock Switch
- Ignition Switch
- Battery
- All Related Wiring & Connections
- Powertrain Control Module (PCM)CAUTION: Before performing any starter tests, ignition and fuel systems must be disabled.
- To disable ignition and fuel systems, disconnect Automatic Shutdown Relay (ASD). The ASD relay is located in Power Distribution Center (PDC). Refer to PDC cover for proper relay location.