Blend Door Output Shorted To Ground
WARNING: This page is about a different car, the 2002 Dodge Intrepid, 2002 Chrysler Intrepid, 2002 Chrysler Concorde, and 2002 Chrysler 300M. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:
After making any repairs, perform BODY VERIFICATION TEST
under VERIFICATION TESTS.
NOTE:
After repair or replacement is completed, calibration must be performed. See AUTOMATIC A/C-HEATER SYSTEMS - CONCORDE, INTREPID & 300M
article or MANUAL A/C-HEATER SYSTEMS - CONCORDE & INTREPID
article in HVAC.
Monitored & Set Condition
- When Monitored: Whenever the BCM attempts to move one of the HVAC actuators.
- Set Condition: When the BCM detects one or more of the following outputs shorted to ground; mode door driver, blend door driver, recirculation door driver or the common door driver.
Possible Causes:
- Blend Air Door Driver Circuit Short To Ground
- Blend Air Door Driver CKT Short To Sensor Ground
- Blend Air Door Driver Wire Short To Sensor Ground
- Blend Door Actuator
Testing
- Turn all lights off. Close the driver door latch to turn courtesy lights off. Disconnect the BCM C1 harness connector. See Figure . Measure the resistance between ground and the blend air door driver circuit. If the resistance is 5 ohms or less, repair the blend air door driver circuit for a short to ground. If the resistance is 5 ohms or more, go to next step.
- Measure the resistance between the blend air door driver circuit and the sensor ground circuit in the BCM C1 connector. If the resistance is 5 ohms or less, go to next step. If the resistance is 5 ohms or more, replace the BCM. See BODY CONTROL MODULE under REMOVAL & INSTALLATION.
- Disconnect the blend door actuator harness connector. See Figure . Measure the resistance between the blend air door driver circuit and the sensor ground circuit in the BCM C1 connector. If the resistance is 5 ohms or less, repair the blend air door driver circuit for a short to the sensor ground circuit. If the resistance is 5 ohms or more, replace the blend door actuator. See BLEND DOOR ACTUATOR under REMOVAL & INSTALLATION.