Crankcase Ventilation System - Testing & Cleaning
The Crankcase Ventilation (CCV) system performs same function as a conventional PCV system, but does not use a vacuum controlled valve. A vacuum fitting containing a fixed orifice of a calibrated size is used. It meters amount of crankcase vapors drawn out of engine.
- Check each CCV system tube (line) for leaks, cracks, kinks or bends. Replace as necessary. Disconnect each CCV tube.
- Blow compressed air through each tube and check for blockage or restrictions. If cleaning is necessary, spray a soapy-type all-purpose cleaner into each component and blow out. After restriction is cleared, rinse out component with clear water. Blow water from component and install to vehicle. To prevent damage to plastic components, never spray carburator-type cleaner into any of plastic tubes or fixed orifice fitting. Never attempt to clean fixed orifice fitting with a metal object as calibration could be affected. If fixed fitting cannot be cleared, replace it.