Incomplete Latch Release - Overcurrent
NOTE:
After making any repairs, perform BODY VERIFICATION TEST under VERIFICATION TESTS.
- Using scan tool, record and erase DTCs. Turn ignition off. Wait approximately 10 seconds. Turn ignition on. Operate power sliding door several times if possible. Recheck for DTCs. If INCOMPLETE LATCH RELEASE - OVERCURRENT resets, go to next step. If INCOMPLETE LATCH RELEASE - OVERCURRENT does not reset, system is okay at this time. Check for intermittent poor connections or faulty circuits.
- Visually inspect sliding door for proper alignment, damaged strikers, damaged latches or obstructions. Repair as necessary. If possible, check operation of sliding door on a known-good vehicle. If sliding door effort is excessive, diagnose power sliding door. See TROUBLE SHOOTING in POWER SLIDING DOORS & LIFTGATE article. If sliding door effort is not excessive, go to the next step.
- With the DRBIII® in Inputs/Outputs, read the FULL OPEN SWITCH state. Open and close the door manually and observe the Full Open Switch. If the switch toggled from open to closed, replace the Latch Assembly. See appropriate POWER SLIDING DOORS & LIFTGATE article. If the switch did not toggle from open to closed, replace the Full Open Switch. See REMOVAL & INSTALLATION in POWER SLIDING DOORS & LIFTGATE article.