Diagnostic Test
- SHIFT MOTOR DTC IS ACTIVE
- SHIFT MOTOR CIRCUIT RESISTANCE AT FRONT CONTROL MODULE (FCM) CONNECTOR
- SHIFT MOTOR CIRCUIT RESISTANCE AT INTEGRATED POWER MODULE (IPM) CONNECTOR
- Disconnect the IPM C2 connector.
- Measure the resistance between the Shift Motor (+) circuit and the Shift Motor (-) circuit at the IPM C2 harness connector.
Is the resistance between 40 and 100 Ohms?
Yes
- Replace the Integrated Power Module (IPM) in accordance with the Service Information.
- Perform the TRANSFER CASE VERIFICATION TEST. See DTC-Based Diagnostics/MODULE, Front Control (FCM) - Standard Procedure .
No
- Go to step 4
- (T101) SHIFT MOTOR (+) POS CIRCUIT OPEN
- Disconnect the Shift Motor/Mode Sensor Assembly harness connector.
- Measure the resistance of the (T101) Shift Motor (+) circuit between the Shift Motor/Mode Sensor Assembly harness connector to the IPM C2 harness connector.
Is the resistance above 5.0 Ohms?
Yes
- Repair the open in the (T101) Shift Motor (+) circuit.
- Perform the TRANSFER CASE VERIFICATION TEST. See DTC-Based Diagnostics/MODULE, Front Control (FCM) - Standard Procedure .
No
- Go to step 5
- (T102) SHIFT MOTOR (-) CIRCUIT OPEN
- Measure the resistance of the (T102) Shift Motor (-) circuit between the Shift Motor/Mode Sensor Assembly harness connector to the IPM C2 harness connector.
Is the resistance above 5.0 Ohms?
Yes
- Repair the open in the (T102) Shift Motor (-) circuit.
- Perform the TRANSFER CASE VERIFICATION TEST. See DTC-Based Diagnostics/MODULE, Front Control (FCM) - Standard Procedure .
No
- Go to step 6
- Measure the resistance of the (T102) Shift Motor (-) circuit between the Shift Motor/Mode Sensor Assembly harness connector to the IPM C2 harness connector.
- (T101) SHIFT MOTOR (+) CIRCUIT SHORTED TO GROUND
- Measure the resistance between ground and the (T101) Shift Motor (+) circuit.
Is the resistance below 5.0 Ohms?
Yes
- Repair the short to ground in the (T101) Shift Motor (+) circuit.
- Perform the TRANSFER CASE VERIFICATION TEST. See DTC-Based Diagnostics/MODULE, Front Control (FCM) - Standard Procedure .
No
- Go to step 7
- Measure the resistance between ground and the (T101) Shift Motor (+) circuit.
- (T102) SHIFT MOTOR (-) CIRCUIT SHORTED TO GROUND
- Measure the resistance between ground and the (T102) Shift Motor (-) circuit at the Shift Motor/Mode Sensor Assembly harness connector.
Is the resistance below 5.0 Ohms?
Yes
- Repair the short to ground in the (T102) Shift Motor (-) circuit.
- Perform the TRANSFER CASE VERIFICATION TEST. See DTC-Based Diagnostics/MODULE, Front Control (FCM) - Standard Procedure .
No
- Go to step 8
- Measure the resistance between ground and the (T102) Shift Motor (-) circuit at the Shift Motor/Mode Sensor Assembly harness connector.
- (T101) SHIFT MOTOR (+) CIRCUIT SHORTED TO (T102) SHIFT MOTOR (-) CIRCUIT
- Measure the resistance between (T101) Shift Motor (+) circuit and the (T102) Shift Motor (-) circuit at the Shift Motor/Mode Sensor Assembly harness connector.
Is the resistance below 5.0 Ohms?
Yes
- Repair the short between the (T101) Shift Motor (+) circuit and the (T102) Shift Motor (-) circuit.
- Perform the TRANSFER CASE VERIFICATION TEST. See DTC-Based Diagnostics/MODULE, Front Control (FCM) - Standard Procedure .
No
- Replace the Shift Motor/Mode Sensor Assembly in accordance with the Service Information.
- Perform the TRANSFER CASE VERIFICATION TEST. See DTC-Based Diagnostics/MODULE, Front Control (FCM) - Standard Procedure .
- Measure the resistance between (T101) Shift Motor (+) circuit and the (T102) Shift Motor (-) circuit at the Shift Motor/Mode Sensor Assembly harness connector.
- FRONT CONTROL MODULE (FCM)
- Using the wiring diagram/schematic as a guide, inspect all wiring harness's and connectors that pertain to this circuit.
Were any problems found?
Yes
- Repair as necessary.
- Perform the TRANSFER CASE VERIFICATION TEST. See DTC-Based Diagnostics/MODULE, Front Control (FCM) - Standard Procedure .
No
- Replace the Front Control Module (FCM) in accordance with the Service Information.
- Perform the TRANSFER CASE VERIFICATION TEST. See DTC-Based Diagnostics/MODULE, Front Control (FCM) - Standard Procedure .
- Using the wiring diagram/schematic as a guide, inspect all wiring harness's and connectors that pertain to this circuit.
- INTERMITTENT WIRING AND CONNECTORS
- The conditions necessary to set this DTC are not present at this time.
- Using the wiring diagram/schematic as a guide, inspect the wiring and connectors.
- While monitoring the scan tool data relative to this circuit, wiggle test the wiring harness and connectors.
- Look for the data to change or for the DTC to reset during the wiggle test.
Were any problems found?
Yes
- Repair as necessary.
- Perform the TRANSFER CASE VERIFICATION TEST. See DTC-Based Diagnostics/MODULE, Front Control (FCM) - Standard Procedure .
No
- Test complete.