Set Conditions
WARNING: This page is about a different variant/trim than selected.
- Set Condition:
The Powertrain Control Module (PCM) continuously monitors Actual Line Pressure and compares it to Desired Line Pressure. If the Actual Line Pressure reading is more than 172.4 kPa (25 psi) higher than the Desired Line Pressure, but is less than the highest Line Pressure ever used in the current gear, the DTC sets.