Diagnostic Test
- PERFORM THE RESTRAINTS SYSTEM VERIFICATION TEST NOTE:
If the ORC has been replaced, the ORC Initialization Procedure must be performed to clear the ORC Unlocked DTC and bring the module to a full state of readiness. Refer to OCCUPANT RESTRAINT CONTROLLER (ORC) - DIAGNOSTIC CODE INDEX . Please perform all steps in the sequence presented following exactly the steps to successfully complete the procedures.
WARNING:Turn the ignition off disconnect the 12-volt battery and wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.
- Remove any special tools or jumper wires and reconnect all previously disconnected components - except the Battery.
If equipped with the keyless ignition, use this ignition on warning.
WARNING:Disconnect the 12-volt battery wait two minutes before proceeding, remove the ORC fuses, connect the 12-volt battery, wait two minutes before proceeding. Cycle the ignition to the On position, then reconnect the ORC fuses. Wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.
If equipped with the standard key ignition, use this ignition on warning.
WARNING:Turn the ignition on, then reconnect the 12-volt battery and wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.
- Connect the scan tool to the Data Link Connector - use the most current software available.
- With the scan tool, erase stored DTCs in all airbag system modules.
- Perform module reset.NOTE:
If equipped with an Airbag On - Off switch, read the DTCs in all switch positions.
- Exercise the Restraints System to duplicate the appropriate monitor conditions for any DTCs that were set.
- Wait one minute, and read active codes, if there are none present, read the stored codes.
- If the scan tool shows any active or stored codes, return to the Table of Contents and follow the path specified for that trouble code. If no active or stored codes are present, the repair is complete.
Are any DTCs present or, is the original condition still present?
Yes
- Refer to OCCUPANT RESTRAINT CONTROLLER (ORC) - DIAGNOSTIC CODE INDEX and perform the appropriate diagnostic procedure.
No
- If the battery was disconnected for any reason, you must perform the Battery Reconnection procedure in the BATTERY SYSTEM - SERVICE INFORMATION .
- If equipped with the keyless ignition, use this ignition on warning.
If equipped with the standard key ignition, use this ignition on warning.
- Repair is complete.
WARNING:Turn the ignition off disconnect the 12-volt battery and wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.
NOTE:Please follow the ignition on warnings for either the standard key ignition or keyless ignition for reintroducing battery voltage to the restraint airbag system.
WARNING:Disconnect the 12-volt battery wait two minutes before proceeding, remove the ORC fuses, connect the 12-volt battery, wait two minutes before proceeding. Cycle the ignition to the On position, then reconnect the ORC fuses. Wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.
WARNING:Turn the ignition on, then reconnect the 12-volt battery and wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.
- Remove any special tools or jumper wires and reconnect all previously disconnected components - except the Battery.