Diagnostic Test
- OCCUPANT RESTRAINT CONTROLLER WARNING:
Turn the ignition off disconnect the 12-volt battery and wait two minutes before proceeding. Failure to follow these instructions may result in possible serious or fatal injury.
WARNING:If the Occupant Restraint Controller is dropped at any time, it must be replaced. Failure to follow the proper precautions can result in accidental airbag deployment. Failure to follow these instructions may result in possible serious or fatal injury.
- Disconnect the ORC harness connector(s).NOTE:
Check connectors - Clean and repair as necessary.
Repair
- Replace the Occupant Restraint Controller in accordance with Service Information. Refer to MODULE, OCCUPANT RESTRAINT CONTROLLER, REMOVAL .
- Perform the RESTRAINTS SYSTEM VERIFICATION TEST. Refer to STANDARD PROCEDURE .
- Disconnect the ORC harness connector(s).