Removal And Installation: Installation
To avoid serious or fatal injury on vehicles equipped with airbags, disable the Supplemental Restraint System (SRS) before attempting any steering wheel, steering column, airbags, airbag curtains, knee blocker, seat belt tensioner, impact sensor or instrument panel component diagnosis or service. Disconnect the IBS/negative battery cable assembly from the negative battery post, then wait two minutes for the system capacitor to discharge before performing further diagnosis or service. This is the only sure way to disable the SRS. Failure to take the proper precautions could result in accidental airbag deployment.
Make sure that the steering column remains in the lowest position setting.
- Telescope the steering column to its extended most position.
- Position the instrument cluster close enough to the instrument panel to access and connect the instrument panel wire harness connector (2a) to the receptacle on the back of the cluster housing.
- Install and securely tighten the four screws (1a) that secure the instrument panel cluster to the instrument panel.
- Position the steering column shroud gap hider (1c) to the instrument panel and install the two fasteners (1a). Be certain the retaining clips (1b) are fully engaged with the instrument panel.
- Install the instrument cluster bezel onto the instrument panel. Refer to BEZEL, INSTRUMENT CLUSTER, REMOVAL AND INSTALLATION .
- Connect the negative battery cable. If equipped with an Intelligent Battery Sensor (IBS), connect the IBS connector.NOTE:
If this Electronic Control Unit (ECU) is being replaced with a new unit, a diagnostic scan tool MUST be used to align the PROXI Configuration data into the new ECU. Follow the routine outlined in the diagnostic scan tool for PROXI Configuration Alignment under Miscellaneous Functions for the ECU menu item.
Refer to MODULE, INSTRUMENT PANEL CLUSTER, MODULE PROGRAMMING .