Possible Causes - Scan Tool Does Not Communicate With Can C (Hub Bus Style)
This diagnostic will not have Diagnostic Trouble Codes to assist in determining no scan tool communication with the vehicle.
Default Actions:
- Vehicle may start and run.
- Wipers and Headlights may be on automatically during an ignition cycle when communication is in default mode.
| Possible Causes |
|---|
| FAULTY SCAN TOOL |
| DATA LINK CONNECTOR |
| DATA LINK CONNECTOR FUSED B (+) CIRCUIT OPEN OR HIGH RESISTANCE |
| DATA LINK CONNECTOR GROUND CIRCUIT OPEN OR HIGH RESISTANCE |
| CAN C (+) BUS CIRCUIT OPEN, SHORTED OR HIGH RESISTANCE |
| CAN C (-) BUS CIRCUIT OPEN, SHORTED OR HIGH RESISTANCE |
| POOR CONNECTION |
| STAR CONNECTOR |
| ANY MODULE ON THE CAN C BUS |
NORMAL CAN CIRCUIT VOLTAGE TABLE
| CIRCUIT | NORMAL VOLTAGE VALUES |
|---|---|
| CAN C (-) | 1.5 - 2.5 volts |
| CAN C (+) | 2.5 - 3.5 volts |