Home >> Dodge and Ram >> 2017 >> Viper Base >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Communication Devices >> Communication - Non-DTC Based Diagnostics >> Diagnosis And Testing >> Scan Tool Does Not Communicate With Can C >> Possible Causes - Scan Tool Does Not Communicate With Can C (Hub Bus Style)
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Possible Causes - Scan Tool Does Not Communicate With Can C (Hub Bus Style)

This diagnostic will not have Diagnostic Trouble Codes to assist in determining no scan tool communication with the vehicle.

Default Actions: 

Possible Causes
FAULTY SCAN TOOL
DATA LINK CONNECTOR
DATA LINK CONNECTOR FUSED B (+) CIRCUIT OPEN OR HIGH RESISTANCE
DATA LINK CONNECTOR GROUND CIRCUIT OPEN OR HIGH RESISTANCE
CAN C (+) BUS CIRCUIT OPEN, SHORTED OR HIGH RESISTANCE
CAN C (-) BUS CIRCUIT OPEN, SHORTED OR HIGH RESISTANCE
POOR CONNECTION
STAR CONNECTOR
ANY MODULE ON THE CAN C BUS
NORMAL CAN CIRCUIT VOLTAGE TABLE

CIRCUIT NORMAL VOLTAGE VALUES
CAN C (-) 1.5 - 2.5 volts
CAN C (+) 2.5 - 3.5 volts
Difference Between CAN C (+) and CAN C (-) 0.5 volt