Set Condition

When an Oxygen Sensor is inactive, the sensor output voltage will stay within a narrow range. If the Oxygen Sensor output voltage is between 0.44 and 0.48 volts for a calibrated period of time, the fault will set. This is a two trip fault. Three good trips are required to turn off the MIL.