Module, Security Gateway (SGW): Installation
NOTE:
If a NEW Security Gateway (SGW) module is being installed, use the diagnostic scan tool to flash the module. Failure to flash the module will leave the SGW module in a locked mode preventing SGW module operation.
- Position the SGW module to the bracket, then install and securely tighten the screws.
- Connect the SGW module wire harness connectors.
- Install the SGW module bracket bolts and securely tighten the bolts.
- Connect electrical connector, position passenger silencer panel (1) on instrument panel and install three tabs.
- Install passenger side cowl panel. Refer to PANEL, COWL TRIM, SIDE, INSTALLATION .
- Connect the negative battery cable. If equipped with an Intelligent Battery Sensor (IBS), connect the IBS connector.
- If a NEW SGW module is installed, use the diagnostic scan tool to flash the SGW module.