LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Dodge and Ram >> 2021 >> Durango SXT Plus, AWD >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Anti-Theft Systems >> (Power Liftgate Module (PLGM) - Electrical Diagnostics) >> DTC Troubleshooting >> B196B-00-Power Liftgate Close Direction - Excessive Time >> Diagnostic Test
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Diagnostic Test

  1. CHECK FOR ACTIVE DTCS 
    1. With the scan tool, record and erase the DTCs.
    2. Cycle the ignition off, wait 10 seconds, then cycle the ignition on.
    3. Operate the power liftgate several times if possible.
    4. With the scan tool, read the Active DTCs.

      Does the scan tool display; B196B-00-POWER LIFTGATE CLOSE DIRECTION - EXCESSIVE TIME?

      Yes 

      • Go To  2

      No 

      • Using the wiring diagram/schematic as a guide, inspect the wiring and connectors for an intermittent condition. Operate the liftgate several times and check for any binding conditions.
      • Perform the BODY VERIFICATION TEST. Refer to BODY VERIFICATION TEST .
  2. CHECK FOR A BINDING LIFTGATE 
    1. Examine the liftgate for proper alignment, worn or binding hinges, stiff liftgate prop assembly, or loose/hard weatherstrip or anything that would cause an obstruction to proper operation.
    2. If necessary manually operate the liftgate of a known good vehicle and notice the effort needed.
    3. Compare the effort needed on the disabled vehicle.

      Were there any mechanical problems found?

      Yes 

      No 

      • Go To  3
  3. OPERATE THE POWER LIFTGATE DRIVE UNIT 
    1. Reconnect all connectors.
    2. Operate the Power Liftgate in both directions if possible.

      Does the motor start to lift or lower the liftgate but moves very slow and labors extensively?

      Yes 

      No