Diagnostic Code Index
DIAGNOSTIC CODE INDEX
| DTC | Description |
|---|---|
| B1CE9-00 | DIGITAL CRASH OUTPUT CONTROL CIRCUIT PERFORMANCE |
| B273C-00 | DIGITAL CRASH INPUT |
| P0562-00 | SYSTEM VOLTAGE LOW |
| P0668-00 | CONTROL MODULE INTERNAL TEMPERATURE SENSOR 1 CIRCUIT LOW |
| P0634-00 | CONTROL MODULE INTERNAL TEMPERATURE 1 TOO HIGH |
| P0668-00 | CONTROL MODULE INTERNAL TEMPERATURE SENSOR 1 CIRCUIT LOW |
| P0A0A-00 | HIGH VOLTAGE SYSTEM INTERLOCK CIRCUIT A |
| P0A0B-00 | HIGH VOLTAGE SYSTEM INTERLOCK CIRCUIT A PERFORMANCE |
| P0A0C-00 | HIGH VOLTAGE SYSTEM INTERLOCK CIRCUIT A LOW |
| P0A0D-00 | HIGH VOLTAGE SYSTEM INTERLOCK CIRCUIT A HIGH |
| P0A1F-00 | BATTERY ENERGY CONTROL MODULE A INTERNAL PERFORMANCE |
| P0A7E-00 | HYBRID/EV BATTERY PACK A OVER TEMPERATURE |
| P0A7F-00 | HYBRID/EV BATTERY PACK DETERIORATION |
| P0A95-00 | HIGH VOLTAGE FUSE A |
| P0A9B-00 | HYBRID BATTERY TEMPERATURE SENSOR A CIRCUIT |
| P0A9D-00 | HYBRID/EV BATTERY TEMPERATURE SENSOR 1 CIRCUIT LOW |
| P0A9E-00 | HYBRID/EV BATTERY TEMPERATURE SENSOR 1 CIRCUIT HIGH |
| P0AA1-00 | HYBRID/EV BATTERY POSITIVE CONTACTOR A STUCK CLOSED |
| P0AA2-00 | HYBRID/EV BATTERY POSITIVE CONTACTOR A STUCK OPEN |
| P0AA4-00 | HYBRID/EV BATTERY NEGATIVE CONTACTOR A STUCK CLOSED |
| P0AA5-00 | HYBRID/EV BATTERY NEGATIVE CONTACTOR A STUCK OPEN |
| P0AA6-00 | HYBRID BATTERY VOLTAGE SYSTEM ISOLATION FAULT |
| P0AA7-00 | HYBRID/EV BATTERY VOLTAGE ISOLATION SENSOR CIRCUIT |
| P0AA8-00 | HYBRID/EV BATTERY PACK A VOLTAGE ISOLATION SENSOR CIRCUIT RANGE/PERFORMANCE |
| P0ABA-00 | HYBRID/EV BATTERY PACK VOLTAGE SENSE A CIRCUIT |
| P0AC0-00 | HYBRID BATTERY PACK CURRENT SENSOR 1 CIRCUIT PERFORMANCE |
| P0AC1-00 | HYBRID BATTERY PACK CURRENT SENSOR 1 CIRCUIT LOW |
| P0AC2-00 | HYBRID BATTERY PACK CURRENT SENSOR 1 CIRCUIT HIGH |
| P0AD9-00 | HYBRID BATTERY POSITIVE CONTACTOR CONTROL CIRCUIT/OPEN |
| P0ADB-00 | HYBRID/EV BATTERY POSITIVE CONTACTOR A CONTROL CIRCUIT LOW |
| P0ADC-00 | HYBRID/EV BATTERY POSITIVE CONTACTOR A CONTROL CIRCUIT HIGH |
| P0ADD-00 | HYBRID BATTERY NEGATIVE CONTACTOR CONTROL CIRCUIT/OPEN- |
| P0ADF-00 | HYBRID/EV BATTERY NEGATIVE CONTACTOR A CONTROL CIRCUIT LOW |
| P0AE0-00 | HYBRID/EV BATTERY NEGATIVE CONTACTOR A CONTROL CIRCUIT HIGH |
| P0AE3-00 | HYBRID/EV BATTERY PRECHARGE CONTACTOR CIRCUIT STUCK OPEN |
| P0AE6-00 | HYBRID/EV BATTERY PRECHARGE CONTACTOR CONTROL CIRCUIT A LOW |
| P0AE7-00 | HYBRID/EV BATTERY PRECHARGE CONTACTOR CONTROL CIRCUIT A HIGH |
| P0B0F-00 | HYBRID/EV BATTERY PACK CURRENT SENSOR 2 CIRCUIT PERFORMANCE |
| P0B10-00 | HYBRID/EV BATTERY PACK CURRENT SENSOR 2 CIRCUIT LOW |
| P0B11-00 | HYBRID/EV BATTERY PACK CURRENT SENSOR 2 CIRCUIT HIGH |
| P0B13-00 | HYBRID/EV BATTERY PACK CURRENT SENSOR 1/2 CORRELATION |
| P0B14-00 | HYBRID/EV BATTERY PACK VOLTAGE SENSE B CIRCUIT |
| P0B33-00 | HIGH VOLTAGE SERVICE DISCONNECT CIRCUIT |
| P0B35-00 | HIGH VOLTAGE SERVICE DISCONNECT CIRCUIT LOW |
| P0B36-00 | HIGH VOLTAGE SERVICE DISCONNECT CIRCUIT HIGH |
| P0B3D-00 | HYBRID/EV BATTERY VOLTAGE SENSE 1 CIRCUIT LOW |
| P0B3E-00 | HYBRID/EV BATTERY VOLTAGE SENSE 1 CIRCUIT HIGH |
| P0BBD-00 | HYBRID BATTERY PACK VOLTAGE VARIATION EXCEEDED LIMIT |
| P0BBE-00 | HYBRID BATTERY PACK VOLTAGE VARIATION |
| P0C44-00 | HYBRID BATTERY PACK COOLANT INLET TEMPERATURE SENSOR CIRCUIT LOW |
| P0C45-00 | HYBRID BATTERY PACK COOLANT INLET TEMPERATURE SENSOR CIRCUIT HIGH |
| P0C6E-00 | HYBRID BATTERY TEMPERATURE SENSOR A/B CORRELATION |
| P0C77-00 | HV BATTERY SYSTEM PRECHARGE TIME TOO SHORT |
| P0C78-00 | HYBRID/EV BATTERY SYSTEM PRECHARGE A TIME TOO LONG |
| P0CA6-00 | HYBRID/EV BATTERY CHARGING CURRENT HIGH |
| P0CA7-00 | HYBRID/EV BATTERY DISCHARGING CURRENT HIGH |
| P0CD7-00 | HYBRID BATTERY PACK COOLANT OUTLET TEMPERATURE SENSOR CIRCUIT LOW |
| P0CD8-00 | HYBRID BATTERY PACK COOLANT OUTLET TEMPERATURE SENSOR CIRCUIT HIGH |
| P0D08-00 | HYBRID/EV BATTERY POSITIVE CONTACTOR A STUCK CLOSED |
| P0D09-00 | HYBRID/EV BATTERY POSITIVE CONTACTOR A STUCK OPEN |
| P0D0A-00 | HYBRID/EV BATTERY POSITIVE CONTACTOR A CONTROL CIRCUIT OPEN |
| P0D0C-00 | HYBRID/EV BATTERY POSITIVE CONTACTOR A CONTROL CIRCUIT LOW |
| P0D0D-00 | HYBRID/EV BATTERY POSITIVE CONTACTOR A CONTROL CIRCUIT HIGH |
| P0D0F-00 | HYBRID/EV BATTERY NEGATIVE CONTACTOR A STUCK CLOSED |
| P0D10-00 | HYBRID/EV BATTERY NEGATIVE CONTACTOR A STUCK OPEN |
| P0D11-00 | HYBRID/EV BATTERY NEGATIVE CONTACTOR A CONTROL CIRCUIT/OPEN |
| P0D13-00 | HYBRID/EV BATTERY NEGATIVE CONTACTOR A CONTROL CIRCUIT LOW |
| P0D14-00 | HYBRID/EV BATTERY NEGATIVE CONTACTOR A CONTROL CIRCUIT HIGH |
| P0D35-00 | HYBRID/EV BATTERY SYSTEM CURRENT UNSTABLE |
| P0DAF-00 | HYBRID/EV BATTERY CELL BALANCING CIRCUIT A RANGE/PERFORMANCE |
| P0DE6-00 | HYBRID/EV BATTERY PACK CELL VOLTAGE LOW |
| P0DE7-00 | HYBRID/EV BATTERY PACK CELL VOLTAGE HIGH |
| P0E2F-00 | HIGH VOLTAGE FUSE B |
| P0E30-00 | HIGH VOLTAGE FUSE C |
| P0E6D-00 | BATTERY CHARGING SYSTEM PRECHARGE CONTACTOR CONTROL CIRCUIT/OPEN |
| P0ECA-00 | HYBRID/EV BATTERY TEMPERATURE SENSOR SYSTEM-MULTIPLE SENSOR CORRELATION |
| P0ECB-00 | HYBRID/EV BATTERY VOLTAGE SENSOR SYSTEM-MULTIPLE SENSOR CORRELATION |
| P1614-00 | ECU RESET/RECOVERY OCCURRED |
| P167B-00 | CONTROLLED SYSTEM SHUTDOWN |
| P1A01-00 | BATTERY ENERGY CONTROL MODULE EEPROM FAILURE |
| P1A06-00 | BATTERY ENERGY CONTROL MODULE READ ONLY MEMORY (ROM) |
| P1A0C-00 | BATTERY ENERGY CONTROL MODULE SYSTEM VOLTAGE LOW |
| P1A0D-00 | BATTERY ENERGY CONTROL MODULE SYSTEM VOLTAGE HIGH |
| P1A20-00 | BATTERY ENERGY CONTROL MODULE HYBRID BATTERY SYSTEM PRECHARGE TIME TOO LONG |
| P1A21-00 | HV BATTERY CONTACTOR CONTROL SEQUENCE INCORRECT |
| P1A29-00 | CELL SUPERVISORY CIRCUIT A FAILURE |
| P1A9A-00 | HYBRID/EV BATTERY TEMPERATURE SENSOR 1 OUT OF RANGE LOW |
| P1A9B-00 | HYBRID/EV BATTERY TEMPERATURE SENSOR 1 OUT OF RANGE HIGH |
| P1AE2-00 | BATTERY ENERGY CONTROL MODULE HIGH VOLTAGE SYSTEM INTERLOCK CIRCUIT |
| P1AE3-00 | BATTERY ENERGY CONTROL MODULE HIGH VOLTAGE SYSTEM INTERLOCK CIRCUIT LOW |
| P1AE4-00 | BATTERY ENERGY CONTROL MODULE HIGH VOLTAGE SYSTEM INTERLOCK CIRCUIT HIGH |
| P1C00-00 | HYBRID/EV BATTERY VOLTAGE SENSE 1 OUT OF RANGE LOW |
| P1C01-00 | HYBRID/EV BATTERY VOLTAGE SENSE 1 OUT OF RANGE HIGH |
| P1DAF-00 | INCOMPATIBLE LIMP IN ACTION REQUESTED |
| P1E15-00 | BATTERY CURRENT SENSOR |
| P1E1A-00 | HYBRID/EV BATTERY CONTROL BOARD HARDWARE PERFORMANCE |
| P1E1B-00 | HYBRID/EV BATTERY SIDE VOLTAGE SYSTEM ISOLATION |
| P1E25-00 | HYBRID/EV BATTERY FAILURE LEVEL 2 |
| P29FF-00 | HYBRID/EV BATTERY THERMAL RUNAWAY DETECTED |
| P2C89-00 | HYBRID/EV BATTERY SYSTEM PRECHARGE A CURRENT TOO HIGH |
| P2C94-00 | HYBRID/EV BATTERY CONTACTOR CONTROL SUPPLY CIRCUIT LOW |
| P2C95-00 | HYBRID/EV BATTERY CONTACTOR CONTROL SUPPLY CIRCUIT HIGH |
| P2D3A-00 | FORCED HYBRID/EV SYSTEM SHUTDOWN |
| U0074-00 | DEDICATED POWERTRAIN-D-PT-CAN BUS OFF |
| U0077-00 | CONTROL MODULE COMMUNICATION BUS OFF |
| U0151-00 | LOST COMMUNICATION WITH OCCUPANT RESTRAINT CONTROLLER (ORC) |
| U0293-00 | LOST COMMUNICATION WITH HYBRID CONTROL MODULE |
| U0294-00 | LOST COMMUNICATION WITH POWERTRAIN CONTROL MONITOR MODULE |
| U029A-00 | LOST COMMUNICATION WITH HYBRID BATTERY PACK SENSOR MODULE |
| U02AE-00 | LOST COMMUNICATIONS WITH HYBRID/EV BATTERY COOLANT PUMP |
| U0594-00 | IMPLAUSIBLE DATA RECEIVED FROM HYBRID CONTROL MODULE |
| U0595-00 | INVALID DATA RECEIVED FROM POWERTRAIN CONTROL MONITOR MODULE |
| U064A-00 | LOST COMMUNICATION WITH HYBRID/EV BATTERY PACK CURRENT SENSOR A |
| U064B-00 | LOST COMMUNICATION WITH HYBRID/EV BATTERY PACK CURRENT SENSOR B |
| U069E-00 | LOST COMMUNICATION WITH COOLANT HEATER B |
| U1008-00 | LIN 1 BUS |
| U3017-00 | CONTROL MODULE TIMER/CLOCK PERFORMANCE |