LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Fiat >> 1976 >> Spider Automatic Trans >> Repair and Diagnosis >> Electrical >> Charging Systems >> MARELLI Alternators >> Testing >> Bench Testing >> Diode Checks
October 30: LEMON manuals on a temporary server, it is slow and having issues, download the manuals you need! Later in November we will switch back to the fast server.

Diode Checks

  1. Connect leads of an ohmmeter to terminal 30 and stator winding connector. Check resistance, then reverse leads and recheck. Both readings should show high resistance with one reading being slightly higher than the other. If both readings are low, a positive diode is bad.
  2. Check resistance between ground and stator winding connector. Reverse leads and check reading. If both readings are low, a negative diode is bad.
  3. Check resistance between energizing diode plug and stator winding connector. Reverse leads and check reading. If both readings are low, an energizing diode is bad.
    Fig 1: Marelli Alternator Test Points
    G09334913Courtesy of NOT AVAILABLE