Choke Cap Resistance
- Adjust ohmmeter to scale indicating maximum of 30 ohms. Connect one ohmmeter lead to choke cap terminal. Connect remaining lead the choke cap clamp. Ensure that all connections are clean and free of oil film.
- Note ohmmeter reading. Reading should remain less than 30 ohms but should not be zero. Repeat test several times, if reading is not within specifications.
- This is to ensure that false reading is not being obtained. Replace choke cap, if reading remains excessive.