Rectifier & Stator Circuit
- Adjust ohmmeter to the x1 scale. Place ohmmeter probe on alternator BAT terminal. Place remaining probe on STA terminal. Note reading. Reverse probes and note reading.
- Perform same test procedure using STA and GRD terminals. An ohmmeter reading in both directions indicates defective negative diode, grounded stator, stator terminal, grounded positive diode plate or BAT terminal.
- There should be an infinite reading in one direction and a low reading in the other direction. A low reading of approximately 6 ohms should be obtained in one direction.
- An ohmmeter reading in both directions indicates defective positive diode, grounded diode plate or BAT terminal.
- Infinite reading with probes in one direction and no reading or excessive resistance in other, indicates bad connection on stator terminal and stator bolt head.