LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 1990 >> F-Super Duty 7.3 M, Automatic >> Repair and Diagnosis >> Engine Performance >> System >> Engine Controls - Tests W/Codes >> Test S - System Check >> Test S: Step 4
September 30: LEMON manuals is back up on a temporary server! Slowness is possible

Test S: Step 4

4) MAP/BP Tester Output Reading  Measure several known good MAP sensors to obtain average measured voltage for specific location and date of testing. With MAP/BP tester and DVOM connected. Turn key on and measure MAP/BP SIG voltage at MAP sensor. If voltage is in the correct range for altitude, go to next step, except vehicles equipped with MA sensors, go to step 8). If voltage is not in the correct range for altitude, replace MAP/BP sensor.

MAP VOLTAGE OUTPUT

Approximate Elevation (Ft.) Output In Volts
0 1.55-1.63
1000 1.52-1.60
2000 1.49-1.57
3000 1.46-1.54
4000 1.43-1.51
5000 1.40-1.48
6000 1.37-1.45
7000 1.35-1.43