Wiring Continuity Check
Turn ignition off. Disconnect EVO actuator valve harness connector. Check the continuity of circuit No. 330 (Yellow/Light Green wire) and circuit No. 353 (Light Blue wire) from EVO actuator valve harness connector to EVO control module pin No. 14. If continuity exists, proceed to QUICK TEST B4 . If continuity does NOT exist, service wires and proceed to QUICK TEST A0 .