Field Open Or Short Circuit Testing
- Perform test before alternator disassembly. Adjust ohmmeter to the x1 scale. Place ohmmeter probe on alternator FLD terminal. Place remaining ohmmeter probe on alternator GRD terminal.
- Rotate alternator pulley and note reading. Ohmmeter reading should be 2.4100 ohms. Reading should fluctuate while pulley is spinning.
- Infinite reading indicates open brush lead, damaged brushes or bad rotor assembly. If ohmmeter reading is less than 2.4 ohms, check for grounded brush assembly, grounded field terminal, or defective rotor.