Torque Converter
- Torque converter is a sealed unit and cannot be disassembled for service. Replace torque converter if it is found to be detective. Remove any rust from pilot hub and boss of converter. Measure pilot bushing inner diameter. If measurement exceeds 2.090" (53.076 mm), replace torque converter.
- Using Converter Cleaner (Rotunda 014-00028), flush torque converter. After converter is removed from cleaner, thoroughly drain solvent through hub. Add about .53 qt. (.5L) clean ATF to converter. Agitate fluid by hand. Thoroughly flush ATF from converter hub.
NOTE:
DO NOT
clean torque converter by hand using solvent.