A7: Check Master Window Regulator Control Switch
- Turn ignition switch off.
- Remove the master window regulator control switch. Leave the electrical connector connected.
- Turn ignition switch to RUN/ACC.
- Using Rotunda Digital Volt-Ohmmeter 017-00407 or equivalent, check for correct voltage at the master window regulator control switch while moving the window regulator control switch. See Fig 1 .