CMP Synchronizer: Installation
- Install Synchro Positioner (T95T-12200-A) on synchronizer assembly (CMP sensor removed). Turn synchronizer shaft clockwise until tool boss engages with notch in synchronizer housing. Tool should fit squarely in top of synchronizer housing.
- Install intermediate shaft in synchronizer assembly. Lubricate synchronizer drive gear with engine oil. Arrow on synchro positioner should point from centerline of engine. See Fig 1
. Insert synchronizer assembly into engine.
- While inserting, synchronizer assembly will rotate. Install and tighten hold-down clamp. When installed, synchro positioner should point 33-45 degrees from engine centerline. If synchro positioner is not pointing in correct direction, remove synchronizer assembly and start again from step 1). If installed correctly, remove synchro positioner.
- Install CMP sensor and tighten screws to specification. See TORQUE SPECIFICATIONS
. Connect CMP sensor harness connector and negative battery cable.
Courtesy of FORD MOTOR CO.