Master Window/Door Lock Control Switch
NOTE:
Power door lock and power window switch is combined into one switch (master window/door lock control switch). This tests only the power door lock circuits of the control switch. See WIRING DIAGRAMS .
- Remove master window/door lock control switch to be tested. With switch in released position, continuity should exist between terminals No. 1 and 4 and between terminals No. 2 and 5. See Fig 1 and Fig 2 . Continuity should not exist between terminal No. 3 and any other terminal. If continuity is as specified, go to next step. If continuity is not as specified, replace power door lock switch.
- With switch in LOCK position, continuity should exist between terminals No. 3 and 4 and between terminals No. 2 and 5. Continuity should not exist between terminal No. 1 and any other terminal. If continuity is as specified, go to next step. If continuity is not as specified, replace power door lock switch.
- With switch in UNLOCK position, continuity should exist between terminals No. 2 and 3 and between terminals No. 1 and 4. Continuity should not exist between terminal No. 5 and any other terminal. If continuity is as specified, power door lock switch is okay at this time. If continuity is not as specified, replace power door lock switch.