GENERATOR SPECIFICATIONS

Application Specification
Generator Amperage Rating 110 Amps
Load Test (1)
With Tester Load (2) (3)
Without Tester Load (4) (5)
No-Load Test (1)(2) 13-15 Volts
(1) All tests are performed with engine running at 2000 RPM.
(2) All accessories off.
(3) Adjust tester load bank to determine generator output.
(4) Perform this test with engine running, A/C on, blower motor on high speed, and headlamps on high beam.