Generator No-Load Test

WARNING: This page is about a different car, the 2003 Ford Windstar and 2002 Ford Windstar. However, it is still accessible from the selected car via links, so may be relevant.

Verify battery condition. Charge or replace battery as necessary. Connect voltmeter positive lead to B+ terminal on generator and negative lead to ground. Start and run engine at 2000 RPM with no electrical load (accessories off). Read voltmeter when voltage stabilizes. Voltage should be 13-15 volts. If voltage is not as specified, repair by symptom. See SYMPTOM INDEX  table under SYSTEM TESTS.