LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2002 >> Crown Victoria Base, 4.6 9 >> Repair and Diagnosis >> Electrical >> Charging Systems >> Charging System - Generators & Regulators >> Generator Specifications
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Generator Specifications

GENERATOR SPECIFICATIONS

Application Specification
Generator Amperage Rating (Maximum) 130 Amps
Load Test
With Tester Load (1) 87 Amps Minimum
Without Tester Load (2) (3)
No-Load Test (1) 13-15 Volts
(1) All accessories off with engine running at 2000 RPM.
(2) Perform this test with engine running at 2000 RPM, A/C on, blower motor on high speed, and headlamps on high beam.
(3) With accessories on, voltage should increase a minimum of 0.5 volt above base voltage.