Memory Set Switch
Disconnect memory set switch. Measure resistances on memory set switch as follows:
- No. 4 and No. 6 while operating memory position No. 1. Resistance should be open when in neutral position and less than one ohm when depressed.
- No 3 and No 6 while operating memory position No. 2. Resistance should be open when in neutral position and less than one ohm when depressed.
- No. 1 and No. 6 while operating memory SET button. Resistance should be open when in neutral position and less than one ohm when depressed.
If resistances are as specified switch is okay. If resistances are not as specified, replace memory set switch and test operation.