Saturn Service Stall Method

WARNING: This page is about a different car, the 2002 Saturn LW300 and 2002 Saturn L300. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: If ignition is turned off before SECURITY indicator light changes state, relearn procedure must be restarted.
  1. Check BCM and ECM for existing DTCs. If DTCs exist, repair as necessary and go to next step. If no DTCs exist, go to next step.
  2. Install scan tool. Turn ignition switch to RUN position. Using scan tool, select Passlock(R) relearn procedure. Wait 10 minutes. When SECURITY indicator light changes from flashing to off, or from on to off, turn ignition switch to OFF position. Vehicle should start on next ignition cycle.