July 1: So it begins. Don't worry, this is not in the correct legal jurisdiction!
Connecting Rod - Twist
Measure the connecting rod twist on a suitable alignment fixture. Follow the instructions of the fixture manufacturer. Verify the measurement is within specification.
If out of specification, install new components as necessary.