LEMON Manuals: Even more car manuals for everyone: 1960-2025
Home >> Ford >> 2003 >> Cutaway 7.3 F >> Repair and Diagnosis >> Electrical >> Charging Systems >> Charging System - Generators & Regulators - Dual Generators >> Generator Specifications
April 5, 2026: LEMON Manuals is launched! Read the announcement.

Generator Specifications

MOTORCRAFT GENERATOR SPECIFICATIONS

Application Specification
Generator Minimum Current Output
110-Amp Generator 87 Amps
Load Test
With Tester Load (1) 87 Amps Minimum
Without Tester Load (2) (3)
Pulley Ratio
Upper 2.49:1
Lower 2.32:1
No-Load Test (1) 13-15 Volts
(1) All accessories off with engine running at 2000 RPM.
(2) Perform this test with engine running at 2000 RPM, A/C on, blower motor on high speed, and headlamps on high beam.
(3) With accessories on, voltage should increase a minimum of 0.5 volt above base voltage.