Generator On-Vehicle Tests - Load Test: Notes

WARNING: This page is about a different car, the 2003 Lincoln LS. However, it is still accessible from the selected car via links, so may be relevant.
  1. Switch the tester to the ammeter function.
  2. Connect the positive and negative leads of the tester to the corresponding battery terminals
  3. Connect the current probe to the generator B+ output terminal, circuit 30-BA6 (RD).
  4. With the engine running at approximately 2,000 RPM, adjust the tester load bank to determine the output of the generator. Generator output should be at least 70 amps.