Generator No-Load Test

Connect voltmeter positive lead to B+ terminal on generator and negative lead to ground. Start and run engine at 2000 RPM with no electrical load (all accessories off). Read voltmeter when voltage stabilizes. Voltage should be 13-15 volts. If voltage is not as specified, see SYMPTOM INDEX  table under SYSTEM TESTS.